|
Three Phase 15kW 37A hybrid inverter for high voltage batteries. It enables enhanced energy independence and maximizes self-consumption through export limit feature and “time of use” function. With the frequency droop control algorithm, this product supports three phase parallel application, and the Max. parallel units is up to 10pcs.
|
An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity all together.
- 100% unbalanced output, each phase
- AC couple to retrofit existing solar system
- Max. 10 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
- Max. charging/discharging current of 37A
- Support storing energy from diesel generator
- High voltage battery, higher efficiency
- 6 time periods for battery charging/discharging
SPECIFICATION:
Battery Input Data
|
|
Battery Type
|
Lithium-ion
|
Battery Voltage Range(V)
|
160-700
|
Max.Charging Current(A)
|
37
|
Max.Discharging Current(A)
|
37
|
Charging Strategy for Li-ion Battery
|
Self-adaption to BMS
|
Number of battery input
|
1
|
|
|
AC Input/Output Data
|
|
Rated AC Input/Output Active Power (W)
|
15000
|
Max AC Input/Output Apparent Power (VA)
|
16500
|
Peak Power (off-grid) (W)
|
1.5 times of rated power,10s
|
Rated AC Input/Output Current (A)
|
22.8/21.8
|
Max AC Input/Output Current (A)
|
25/24
|
Max Continuous AC Passthrough (grid to load) (A)
|
80
|
Rated Input/Output Voltage/Range (V)
|
220/380V, 230/400V 0.85Un-1.1Un
|
|
|
Efficiency
|
|
Max Efficiency
|
97.6%
|
Euro Efficiency
|
97.0%
|
|
|
Equipment Protection
|
|
Integrated
|
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
|
Surge Protection Level
|
TYPE II(DC), TYPE II(AC)
|
|
|
Interface
|
|
Communication Interface
|
RS485/RS232/CAN
|
Monitor Mode
|
GPRS/WIFI/Bluetooth/4G/LAN (optional)
|
|
|
General Data
|
|
Operating Temperature Range
|
-40 to+60°C>45°C Derating
|
Permissible Ambient Humidity
|
0~100%
|
Noise
|
<55 dB(A)
|
Ingress Protection(IP) Rating
|
IP 65
|
Inverter Topology
|
Non-Isolated
|
Over Voltage Category
|
OVC II(DC), OVC III(AC)
|
Cabinet size (W*H*D) [mm]
|
422 x 658 x 254 (Excluding Connectors and Brackets)
|
Weight[kg]
|
30.5
|
Type Of Cooling
|
Intelligent air cooling
|
Grid Regulation
|
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
|
Safety EMC/Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
|
The instruction, PDF To discuss at a forum
|